BDA and ERRCS Installation and Testing in Denver

Coverage tests, design, permitting, installation, and annual and 5-year testing for emergency responder radio systems, from one Denver Fire Department-licensed team.

Call (720) 441-2137 · Request a coverage test or bid

When firefighters enter a Denver building, their radios have to work in stairwells, parking levels, fire pump rooms and elevator lobbies. Denver Fire Code Section 510 and Denver Fire Department (DFD) Policy 510-1 set when a building needs emergency responder radio coverage, how a bi-directional amplifier (BDA) or ERRCS must be built, and how often it must be tested. Life-Safety Services LLC handles the work from the first coverage test through installation, annual testing and 5-year surveys, under Denver Fire Department license LIC00254065.

Coverage testing: do you need an ERRCS?

Not every building needs a system. High-rise, underground and airport buildings require approved coverage. Other new buildings that meet Denver's size or occupancy triggers must be tested at substantial completion, and they need an ERRCS only if they fail. Existing buildings can be pulled into testing when they install a mass notification system or replace the fire alarm head-end. We run the grid test, document the results, and tell you clearly whether a system is required or whether you only need to keep the "not needed" paperwork on site.

Design, permitting and installation

When a building needs a system, we design a standalone public-safety ERRCS to Denver §510 and NFPA 1225. That includes donor antenna aiming, BDA placement, distribution cabling or antennas, UPS and battery backup, fire-alarm supervisory connections, required signage, shop drawings for plan review, and the construction permit through Denver's e-permits system. Denver allows one public safety BDA per connected building, and only a DFD-licensed contractor may install or modify the system. We coordinate with the DFD Line Shop through acceptance testing so the job closes cleanly.

Annual and 5-year BDA testing

Denver requires an operational permit for annual and 5-year testing. Annual testing covers visual inspection, amplifier health, supervisory signals to the fire alarm panel, UPS performance and signal checks in critical areas. Every five years the building also needs a full new RF grid survey and coax sweep, with results sent to DFD Fire Prevention and the Line Shop, and a witnessed inspection. We schedule the work, keep the ERCES logbook current, and hand you documentation ready for the fire inspector.

Repair and emergency response

DFD Policy 510-1 expects RES deficiencies to be repaired quickly (confirm the current deadline with Fire Prevention; the published policy cites 72 hours). We diagnose amplifier, UPS, donor antenna and cabling problems, pull the right permits for repairs, and call the Line Shop back for retest when the work is done. If the repair takes your fire alarm out of service, Denver's system-down and fire watch rules can apply. Read our Denver BDA/ERRCS guide or call 24/7 emergency service.

Why property managers call us for BDA work

  • Denver Fire Department license LIC00254065 and NICET-certified technicians

  • One team for BDA/ERRCS, fire alarm, sprinklers, dampers, extinguishers, backflow, kitchen hood suppression, fire pumps and hydrants

  • Design and testing that follow Denver Fire Code §510 and DFD Policy 510-1

  • Line Shop coordination for acceptance and 5-year tests

  • 24/7 emergency service: call (720) 441-2137

  • Serving Denver and communities across Colorado from 800 E 64th Ave Unit 10

Frequently asked questions

Does every Denver building need a BDA?
No. High-rise, underground and airport buildings need approved coverage. Other buildings meeting Denver's size or occupancy triggers must be tested, and they need an ERRCS only if coverage fails.

How often does a BDA have to be tested in Denver?
Every year, plus a full RF grid survey every five years. Both need an operational permit, and the 5-year test is witnessed by the DFD Line Shop.

Can the BDA share equipment with a cell phone DAS?
No. Denver requires a standalone system dedicated to public safety, with no shared components.

What signal level does Denver require?
Stronger than −100 dBm across 95% of each floor, and across 99% of critical areas such as stairways, fire pump rooms, fire command centers and elevator lobbies.

Do you only test systems you installed?
No. We can take over annual and 5-year testing for existing systems. Send us your last test report and logbook status and we will quote the next cycle.

Get a BDA quote or schedule a test

Call (720) 441-2137 or book a coverage test, survey or bid. Life-Safety Services LLC, 800 E 64th Ave Unit 10, Denver, CO 80229.

For the full code walkthrough, see Denver BDA & ERRCS Requirements: Building Owner Guide.